Unfortunately, nitrous oxide also acts as a potent greenhouse gas and is produced, for example, by the use of fertilisers in agriculture. In times of climate change, the reliable monitoring of anthropogenic N2O emission sources becomes all the more important.
smartGAS offers a tailor-made technology for N2O
measurement with its reliable non-dispersive infrared absorption (NDIR)
sensors for gas analysing.
The sensors are not only particularly stable
over the long term, but also require little maintenance and have a long
service life, so that they guarantee reliable measurement even in
remote locations.
The FLOWEVO sensor for nitrous oxide covers the complete measuring range from 0 to 500 ppm
with a digital resolution of 1 ppm (parts per million) and, like all
smartGAS gas sensors, is matched to the individual application,
pre-calibrated and delivered ready for operation.
The detection limit is
≤ 0.6 ppm with a repeatability of ≤ ±2.5 ppm.
The BASICEVO sensor for nitrous oxide covers the complete measuring range from 0 to 500 ppm in Air
with a digital resolution of 1 ppm (parts per million) and, like all
smartGAS gas sensors, is matched to the individual application,
pre-calibrated and delivered ready for operation.
The detection limit is
≤ 5 ppm with a repeatability of ≤ ±4 ppm.