Leak detection in air-conditioning technology – NDIR sensors for refrigerants
In refrigeration and air-conditioning technology, the continuous monitoring of the cooling process is vital. Especially in the foodstuffs industry, refrigerating plants have to function reliably, so the availability of the plants is one of the essential advantages in competition. This is the case during the manufacturing of foodstuffs as well as during the transportation and storage of perishable goods. With our refrigerant sensors from the BASICEVO line, we offer you reliable NDIR technology and therefore the opportunity to optimise operating costs considerably and increase the availability of systems. BASICEVO refrigerant sensors are available as a broadband solution for applications where several refrigerants should be measured with one set-up as well as with sensors specifically calibrated to the target gases for the maximum measurement accuracy.
Detailed information on the product
Here you will find an overview of the product data sheets. Please contact us for an individual consultation.
R22
1000 ppm | B3-702105-03000
2000 ppm | B3-702205-03000
R23
Auf Anfrage
R32
Auf Anfrage
R123
1000 ppm | B3-732105-03000
2000 ppm | B3-732205-03000
R125
1000 ppm | B3-722105-03000
2000 ppm | B3-722205-03000
R134a
1000 ppm | B3-712105-03000
2000 ppm | B3-712205-03000
R404a
1000 ppm | B3-742105-03000
2000 ppm | B3-742205-03000
R407a
1000 ppm | B3-752105-03000
2000 ppm | B3-752205-03000
R407c
1000 ppm | B3-802105-03000
2000 ppm | B3-802205-03000
R410a
1000 ppm | B3-762105-03000
2000 ppm | B3-762205-03000
R448a
2000 ppm | B3-832205-03000
R449a
2000 ppm | B3-842205-03000
R452a
Auf Anfrage
R455a
Auf Anfrage
R507
1000 ppm | B3-772105-03000
2000 ppm | B3-772205-03000
R513a
2000 ppm | B3-852205-03000
R1234yf
1000 ppm | B3-782105-03000
2000 ppm | B3-782205-03000
R1234ze
1000 ppm | B3-812105-03000
2000 ppm | B3-812205-03000
broadband refrigerants
2000 ppm | B3-712205-03800
BASICEVO – broadband solution for R134a, R125, R404a, R407a, R410a, R448a, R449a, R407f
With the broadband refrigerant sensors, smartGAS offers a solution in which several gases can be measured in one hardware design. The broadband refrigerant sensors are factory calibrated to 2000 ppm R134a, but are also excellent for the measurement of R125, R404a, R407a, R410a R448a, R449a and R407f. By using simple conversion factors, which are can be stored in the gas warning device, the measured values can be corrected for an accurate measurement.
Air-conditioning technology – the F-gas regulation
According to the F-gases directive, leak detection systems for HFC refrigerants must be installed in certain refrigerating plants. The substances used as refrigerants in air-conditioning technology (R22, R134a, R404a, R125, R123, etc.) are almost always extremely harmful for the environment. The installation of a refrigerant gas warning device is therefore indispensable for the prompt detection of gas due to a leak. Our particularly robust and pre-calibrated BASICEVO detects refrigerants and thus gives early indication of a leak.